Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
Figure 5.14 – Control Module – Contactor Assembly (continued)
5.5.1 Removal
FIRST REMOVE
1. Remove motor (subassembly #4). (See Section 4.1.1.)
2. Remove Accutronix control panel (subassembly #7). (See Section 5.1.1.)
3. Remove control module (subassembly #8). (See Section 5.2.1.)
4. Remove terminal block (subassembly #15). (See Section 5.4.1.)
STEP 1
Using an M3 hex key, loosen the two 4 mm screws (#8-28) that
mount the contactor assembly to the actuator.
5-24
Flow Control Division
Limitorque Actuation Systems
Electronic Assemblies
1
8-28
1
5
4
3
2
L1L1
L2L2
3
L3L3
5
NCNC
2121
2
4 6 2222
T1T1 T2T2 T3T3
A1A1
A2A2
1
L1L1
L2L2
3
L3L3
5
NCNC
2121
2
4 6 2222
T1T1 T2T2 T3T3
A1A1
A2A2
1
TO POWER BOARD (P3 & P1)
AMP SHUR-PLUG
CONNECTOR
5 PIN AMP MATE-n-LOCK
PLUG HOUSING
TO OPTION BOARD (P4)
(CONNECTOR No. 1)
2 PIN AMP MATE-N-LOCK
PLUG HOUSING
TO MOTOR (P1)
CONNECTORS 4 AND 5
(CONNECTOR No. 4)
1
2
3
4
5
6
2
1
6 PIN MOLEX
RECEPTACLE
2 PIN MOLEX
RECEPTACLE
(CONNECTOR No. 2)
(CONNECTOR No. 3)
2
1
2
1
2 PIN AMP MATE-N-LOCK
PLUG HOUSING
(CONNECTOR No. 5)