Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
4.2.2 Remounting
STEP 4
(MX-20 & 40 only) Remove the following subassemblies before
remounting the declutch assembly. (See corresponding referenced
sections for removal information.)
1. Handwheel (subassembly #13). (See Section 4.3.1.)
2. Handwheel adapter (subassembly #12).
(See Section 4.13.1.)
3. Clutch and clutch ring (subassembly #16).
(See Section 4.15.1.)
Lightly lubricate the o-ring (#5-15) and fit it to the inner ace of the
declutch cover (#5-1).
STEP 5
CAUTION
(MX-20 & 40 only) To create proper mating between the cam latch
(#5-6) and the shoulder on the worm gear, ensure cam latch is positioned
below the worm gear shoulder (see Picture 5a).
Tip: (MX-20 and 40 only) – Picture 5a shows proper alignment
between the cam latch (#5-6) and the shoulder on the worm gear.
Tip: (MX-20 & 40 only) – Picture 5b shows improper alignment
between the cam latch (#5-6) and the shoulder on the worm gear.
Improper alignment could cause the cam latch to be broken off
by the worm gear lug.
Tip: (MX-85 & 140 only) – Picture 5c shows proper alignment between
the cam and the clutch ring roller.
4-8
Flow Control Division
Limitorque Actuation Systems
Mechanical Assemblies
4
5-15
Cam latch & worm
gear shoulder
alignment
Cam latch & worm
gear shoulder
improper alignment
5a
5b
5c