Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
4-2
STEP 2
CAUTION
The rotor is not connected to the motor housing; when removing
the motor, ensure the rotor is carefully removed and not dropped from the
motor housing.
Withdraw the complete motor (subassembly #4), including the rotor
(#4-3), until the wiring harness is accessible. Note the O-ring (#1-15)
on the spigot/pilot of the motor assembly; replace at remounting.
STEP 3
Disconnect the motor power plug from the motor power socket
connector.
4.1.2 Remounting
STEP 4
a WARNING
Hazardous Voltage! Turn off all power sources to actuator
before removing motor assembly. Power sources may include main power or
control power.
Lightly lubricate o-ring (#1-15) that is installed around the motor
spigot/pilot (subassembly #4).
2
3
4
1-15
4-3
1-15