Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
STEP 3
Using a 6 mm hex key, remove the M8 screws (#13-9) from the hand-
wheel worm shaft cap (#13-2).
4.6.2 Installing Side-Mounted Handwheel
STEP 4
Install bearing (#13-8) from side-mounted handwheel adapter kit into
the actuator housing.
MX-10, 20 & 40 – the bearing is a slip fit into the housing.
MX-85 & 140 is a press fit into the housing.
STEP 5
Replace the handwheel adapter (#12) with the handwheel worm gear
(#12) that is included in the side-mounted handwheel adapter kit.
4-28
Flow Control Division
Limitorque Actuation Systems
Mechanical Assemblies
3
4
5
13-9
13-2
13-8
Handwheel
Worm Gear
Adapter (12)