Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
5.8.2 Remounting
STEP 3
Work the three connectors through the hole/slot in the housing. (Hole/slot is located in the motor
cavity next to the worm shaft bore.) Thread the three connectors through the housing into the controls
compartment cavity until the lead seal fits completely into the hole/slot in the housing.
STEP 4
Remount all removed subassemblies according to the remounting instructions in the following order.
1. Contactor assembly (subassembly #8). (See Section 5.5.1)
2. Control module (subassembly #15). (See Section 5.4.1)
3. Accutronix control panel (subassembly #7). (See Section 5.1.1)
4. Motor (subassembly #4). (See Section 4.1.1)
5-34
Flow Control Division
Limitorque Actuation Systems
Electronic Assemblies
3a
3b
3c
Rotate
CCW 90˚
Top
This side down