Flowserve Limitorque Accutronix MX - Removal with Type A1;A1 E Base (Thrust)

Flowserve Limitorque Accutronix MX
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remove Actuator from Mounting Adapter
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
3.2 Actuator Removal with Type A1/A1E Base (Thrust)
NOTE: Two procedure options are available for removing the actuator and thrust base:
1. Remove actuator from thrust base, leaving thrust base mounted to mounting flange or removing
thrust base separately.
2. Remove actuator and thrust base as a unit from mounting flange.
3.2.1 Removal (Type A1/A1E Base)—
Actuator removal separate from thrust base
STEP 1
a WARNING
Hazardous Voltage! Turn off all power sources to
actuator before removing actuator from mounting plate. Power
sources may include main power or control power. If necessary,
disconnect incoming power leads L1, L2, L3, and control wiring from
the terminal block.
Remove the bolts (#10-10) that secure the actuator to the
thrust base assembly (#10).
STEP 2
a WARNING
Potential high-pressure vessel! Before disassembling
your actuator, ensure that the valve or other actuated device is
isolated and is not under pressure.
Lift actuator from thrust base assembly (#10).
3-3
Flow Control Division
Limitorque Actuation Systems
1
2
10-10
10
10

Table of Contents