Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
Figure 4.22 – Handwheel (MX-05)
4.13.1 Removal
FIRST REMOVE
1. Remove actuator from mounting adapter.
2. Drain oil.
3. Remove top-mounted handwheel (#1-8). (See Section 4.3.1.)
4. Remove motor (subassembly #4). (See Section 4.1.1.)
5. Remove worm shaft (subassembly #3). (See Section 4.10.1.)
6. Remove base plate (subassembly #11). (See Section 4.9.1.)
7. Remove drive sleeve (subassembly #2). (See Section 4.11.1.)
STEP 1
a WARNING Potential to operate while dangerous mechanical parts are
exposed during subassembly removal. To prevent injury, turn off all power
sources to actuator before removing handwheel adapter assembly. Power
sources may include: main power or control power.
Remove handwheel spacer (#1-9).
4-50
Flow Control Division
Limitorque Actuation Systems
Mechanical Assemblies