Mechanical Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
STEP 2
Unwind wave spring (#1-10) and remove.
STEP 3
NOTE: The handwheel adapter for the MX-05 is removed and intro-
duced from the base of the actuator housing.
Push adapter assembly (#12) from the top of the actuator out
through the bottom of the actuator housing.
4.13.2 Remounting
STEP 4
NOTE: Lightly lubricate quad rings/o-rings before remounting
subassemblies.
With handwheel screw taps facing toward the nameplate side of the
actuator, slide handwheel adapter assembly (#12) into the actuator
housing’s drive sleeve bore. Use hammer handle or similar device to
push handwheel adapter assembly against shoulder inside actuator
housing.
4-51
Flow Control Division
Limitorque Actuation Systems
2
3
4
1-10
Handwheel
adapter assy 12
Handwheel adapt.
screw taps