Mechanical Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
4.4.1 Removal of Side-Mounted Handwheel for MX-20 & 40
NOTES:
The MX-10 & 20 Handwheel is mounted with a roll pin (13-7). If
removal of the handwheel from the worm shaft is necessary, remove
the handwheel and worm shaft assembly from unit before removing
roll pin. Removing the roll pin before disassembly of worm shaft will
damage the ball bearing
(13-3).
The MX-85 & 140 Handwheel is mounted with a key (13-7) and a set
screw (13-18). See pictures a & b.
4-14
Flow Control Division
Limitorque Actuation Systems
b
a