Remove Actuator from Mounting Adapter
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
3.1.2 Remounting (Type B1/B4/B4E Base)
STEP 3
Ensure stem nut (#1-22) is secured inside actuator drive sleeve with
retaining ring (#1-23). Lower actuator onto the mating component,
making sure to align stem nut key and keyway with mating
component.
STEP 4
Ensure that the actuator and mounting adapter flange
mating holes are aligned correctly.
STEP 5
a WARNING
: Hazardous Voltage! Turn off all power sources before rewiring
incoming power leads L1, L2, L3, and control wiring in the terminal block.
Secure the actuator to the mounting adapter with
mounting bolts.
STEP 6
Reconnect incoming power leads L1, L2, L3, and control
wiring to the terminal block. Restore power source when
ready for operation.
3-2
Flow Control Division
Limitorque Actuation Systems
3
4
5
1-22
1-23