Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
4.4.3 Remounting
STEP 4
Check that bearing (#13-8) is correctly in place in the
actuator housing.
The MX-10 & 20 is a slip fit (4a).
The MX-85 & 140 is a press fit (4b).
STEP 5
Insert the complete subassembly into the actuator housing, rotating
counterclockwise (CCW) to properly mesh the gearing. Ensure the end
of the worm shaft is seated in the inner bearing (#13-8).
STEP 6
Position the worm shaft cap (#13-2) back on the actuator housing.
Using a 6 mm hex key, fit the (#13-9) screws onto the worm shaft cap
to secure side-mounted assembly to the actuator housing.
4-16
Flow Control Division
Limitorque Actuation Systems
Mechanical Assemblies
4a
5
6
13-8
Rotate
handwheel
counter clockwise
(ccw)
4b
MX-10 & 20
MX-85 & 140