Mechanical Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
STEP 6 (MX-20 & 40 ONLY)
Place o-ring (#12-4) around handwheel adapter; pressing the o-ring
into the slot between the handwheel worm gear adapter assembly
(#12) and the actuator housing (approximately every 15˚ to 30˚ until
o-ring seats into slot).
STEP 7
Place the retainer plate (#1-32) on the top of the actuator housing.
Align the mounting taps and secure with screws (#1-33).
STEP 8
Complete the remounting procedure for side-mounted
handwheel assembly #13A (MX-10 & 20) or #13B (MX-40)
as detailed in Section 4.4.2 or Section 4.5.2.
4-29
Flow Control Division
Limitorque Actuation Systems
6
7
12-4
1-32