Mechanical Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
Fit the complete declutch assembly into the actuator housing, slightly
twisting, if necessary, to remount into actuator.
STEP 6
Set screw adjustment. Install drive sleeve, baseplate, clutching and
handwheel worm gear components. Assure the clutch lugs are fully
engaged to the motor worm gear lugs before the adjustment. With
declutch lever resting on cap pad (not the set screw) place declutch
cap assembly (1-4) into housing without mounting screws. Rotate cap
assembly clockwise until declutch cam is resisted by the roller, clutch
ring and clutch combination. Holding the declutch lever, rotate the set
screw clockwise thru declutch cap, (this will rotate the cap
counterclockwise) until the cap mounting holes are inline with the
taps in the housing. Install declutch assembly mounting screws. Then
rotate set screw counterclockwise 1/4 plus or minus 1/8 turn.
Adjustment is complete.
STEP 7
Fit the two M6 (MX-05 & 10) screws (#5-12), M8 (MX-20 & 40) screws
to retain the declutch assembly cover (#5-1) on the housing. Tighten
using a 5 mm (MX-05 & 10) or 6 mm (MX-20, 40 & 85) hex key. Picture
7a shows the 2 screws for the MX-20 & 40. Picture 7B shows the 4
screws for the MX-85.
See picture 7a for MX-05, 10, 20 & 40. See picture 7b for
MX-85 & 140.
4-9
Flow Control Division
Limitorque Actuation Systems
7b
5d
7a