Electronic Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
STEP 2
Pull the complete encoder straight out of the mounting
holes to disengage the gear drive from the encoder drive
cartridge pinion.
5.6.2 Remounting
STEP 3
a WARNING: Hazardous Voltage! Turn off all power sources to
actuator before remounting encoder assembly. Power sources may
include main power.
If actuator uses drive sleeve speed I.D. 1 or 2, ensure
optional encoder input gear (#6-24) is installed on encoder
(see NOTE on page 5-24 for details). Align the three
encoder mounting holes with the matching holes in the
actuator housing and push the encoder straight on to the
mounting boss, carefully positioning the encoder to ensure
correct meshing with the encoder drive cartridge pinion. If
needed to align gearing, declutch actuator and turn
handwheel until encoder gear engages with drive cartridge
pinion). Fit the three M4 screws (#1-36) and tighten using a
3 mm hex key. Do not overtighten.