Electronic Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
5.7.1 Removal
FIRST REMOVE
1. Drain oil.
2. Remove ACP cover (subassembly #7). (See Section 5.1.1.)
3. Remove control module (subassembly #8).
(See Section 5.2.1.)
4. Remove encoder (subassembly #6). (See Section 5.6.1.)
STEP 1
a WARNING:
Hazardous Voltage! Turn off all power sources to
actuator before removing encoder drive cartridge. Power sources
may include main power or control power.
Remove the M4 screw (#14-8) using a 3 mm hex key.
STEP 2
Withdraw the complete encoder drive cartridge from the
actuator housing.
5.7.2 Remounting
STEP 3
If actuator uses drive sleeve speed I.D. 1 or 2, ensure input
gear (#6-25) is installed on encoder (see NOTE on page
5-28 for details). Fit the encoder drive cartridge into the
actuator housing.