Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
4-24
Flow Control Division
Limitorque Actuation Systems
Mechanical Assemblies
STEP 9
Ensure o-ring (MX-40) (#13-6) is in place on worm shaft plate.
MX-40, 85, & 140 Insert worm shaft assembly into actuator housing.
Rotate assembly in counterclockwise (CCW) direction to properly mate
with handwheel worm gear assembly (#12)(9b).
STEP 10a - MX-40
Secure with four M8 screws (#13-9) to secure the adapter
plate (#13-2).
STEP 10a & b - MX-85 & 140
Ensure gasket (#13-6) is placed on adapter (#13-2) and install
adapter to housing and secure with four M8 screws (#13-9).
13-9
13-2
10b
10c
10a
9a
13-2
13-6
9b