STEP 4
NOTE: Lightly lubricate o-ring (#3-7) before remounting worm shaft
(subassembly #3).
Lightly lubricate o-ring (#3-7) on the worm shaft (subassembly #3).
Push the complete worm shaft assembly into the actuator housing
until the worm contacts the worm gear. Turn the worm so it engages
the worm gear and continue rotating until the end of the worm shaft
is isolated in the inboard bearing (#3-4).
MX-85 & 140 only:
Be sure the motor wiring harness is pushed in, then rotate worm shaft
cap (#3-2) around so that tab is holding wiring harness in place. See
Section 5.8 for motor wiring harness installation.
STEP 5
Using a hex key, fit the four M6, M8, or M10 screws (#3-9) into worm
shaft cap (#3-2) mounting holes and tighten.
5a
3-9
3-2
5b
4a
4b
Motor
Wiring
Harness
Mechanical Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002 4-41
Flow Control Division
Limitorque Actuation Systems
3-7