Mechanical Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
4.12.a MX-85 & 140
Optional Drive Sleeve and Baseplate Removal
FIRST REMOVE
1. Remove actuator from mounting adapter.
2. Drain oil.
3. Remove thrust base (subassembly #10) - if fitted. (See Section 4.8.1.)
4. Remove motor (subassembly #4). (See Section 4.1.1.)
5. Remove worm shaft (subassembly #3). (See Section 4.10.1.)
6. Remove top-mounted handwheel (#1-8) or side-mounted handwheel (subassembly #16).
(See Section 4.3.1 or 4.4.1.)
7. Remove handwheel adapter (subassembly #12). (See Section 4.14.1.)
8. Remove clutch and clutch ring (subassembly #16). (See Section 4.15.1.)
9. Remove handwheel declutch (subassembly #5). (See Section 4.2.1.)
STEP 1
Lay actuator on its side with the drive sleeve horizontal. Using a hex
key, remove seven of the baseplate screws (#11-5).
STEP 2
Lay actuator on a table or suitable structure with one of the screws
(#11-5) hanging over the edge. Remove screw. If needed, rotate actu-
ator around and remove all other screws.
STEP 3
With help, lift housing straight up and off baseplate and drive sleeve
assemblies.
4-47
Flow Control Division
Limitorque Actuation Systems
1
2
3

Table of Contents

Other manuals for Flowserve Limitorque Accutronix MX