Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
4-60
Flow Control Division
Limitorque Actuation Systems
Mechanical Assemblies
4.15.1 Removal
FIRST REMOVE
1. Drain oil.
2. Remove top-mounted handwheel (#1-8) or side-mounted
handwheel (subassembly #13). (See Section 4.3.1, Section
4.4.1, or Section 4.5.1.)
3. Remove handwheel adapter (subassembly #12).
(See Section 4.14.1.)
STEP 1
a WARNING
Potential to operate while dangerous mechanical
parts are exposed during subassembly removal. To prevent injury,
turn off all power sources to actuator before removing clutch and
clutch ring components. Power sources may include: main power
or control power.
Remove spring spacer (#1-40).
STEP 2
Remove clutch spring (#1-39) that is positioned over the
drive sleeve assembly (#2).
STEP 3
Remove clutch (#1-38).
2
3
1
1-39
2
1-38
1-40