Mechanical Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
STEP 5b, c, d (MX-85 & 140) continued
Fit the clutch ring (#1-37) over the drive sleeve. With the roller (#15-2)
down and holding the latch (#15-7) 90˚ from free position. See 5c.
NOTE: The clutch ring socket head cap screw (#15-9) must fit
into hole in housing to keep ring from rotating. See 5d.
See Warning Note in Section 4.14.2, Step 8.
4-63
Flow Control Division
Limitorque Actuation Systems
5d
Housing hole for clutch
ring screw for anti-rotation of
clutch ring assembly
5c

Table of Contents