Electronic Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
STEP 13
Connect the AMP® power connector to the fuse section on
the main power board.
STEP 14
Connect the 20-pin Molex® harness to plug P1 on the main
processor board.
STEP 15
Connect the 4-pin Molex® harness to plug P4 on the main
processor board.
STEP 16
If DDC board is installed, connect 10-pin Molex® harness to
plug P2 on DDC board (network processor board).
5-9
Flow Control Division
Limitorque Actuation Systems
13
14
15
16
AMP Plug
P1
P4
P2