Introduction and Specifications
Additional Specifications
1
1-31
1-33. AC Voltage, Square Wave Characteristics
Risetime
@ 1 kHz
Typical
Settling Time
@ 1 kHz
Typical
Overshoot
@ 1 kHz
Typical Duty Cycle Range Duty Cycle Uncertainty
<1 µs <10 µs to 1%
of final value
<2% 1% to 99%, <3.3 V p-p,
0.01 Hz to 100 kHz
± (0.8% of period +100 ns)
± (0.02% of period + 100 ns),
50% duty cycle
± (0.05% of period + 100 ns),
other duty cycles from 10%
to 90%
1-34. AC Voltage, Triangle Wave Characteristics (typical)
Linearity to 1 kHz Aberrations
0.3% of p-p value, from 10% to 90% point <1% of p-p value, with amplitude >50% of range
1-35. AC Current (Sine Wave) Extended Bandwidth Specifications
Range Frequency
1-Year Absolute Uncertainty
tcal ± 5 °C
± (% of output + % of range)
Max
Current
Resolution
All current ranges, <330 mA 0.01 Hz to 10 Hz 5.0 + 0.5 2 digits