Description
Char
Value Format
Poll
Burst
Set
Legal Values
Factory Default
Video relative reticle diameter
RC
n.n nn.nn
Ratio Spectral Correction Gain
RSG
1.0
Ratio Spectral Correction
Intercept
RSO
0.0
Reset
RST
Video relative reticle X-position
RX
n.n nn.nn
Video relative reticle Y-position
RY
n.n nn.nn
Slope
S
n.nnn
0.850 1.150
1.000
Alarm source
SAS
0 = object temperature
1 = internal temperature
0
Invalid current sample filter
SF
n
0 = off
1 = on
Please contact technical support
for guidance on use.
0
Slope source
SS
X
I = set by a constant number
according to the command "S"
E = set by the analog input
I
Set target temperature
STT
n.n nnnn.n
min/max of temperature range (°C
or °F)
Set at factory
calibration
Target temp: 2C
T
n.n - nnnn.n
Terminator resistor
TR
n
0 = OFF, 1 = ON
0
TCP/IP time out interval
TTI
n - nnn
0 = , 1 240 s
120
Temperature units (scale)
U
X
C or F
non-US: C
Poll/burst mode
V
X
B = Burst , P = Polled
P
Target temp:1C wide
W
n.n - nnnn.n
Web server
WS
n
0 = OFF, 1 = ON
0
Burst string content
X$
Multidrop address
XA
nnn
000 to 032
000
Low temperature limit
XB
n.n - nnnn.n
0.09999.0
Set at factory
calibration
Deadband
XD
nn
01 50 °C / 1.8 90 °F
No effect if relay in alarm mode.
02
Decay rate
XE
nnnn
0-9999°C/°F
0
Restore factory defaults
XF
Transmissivity
XG
n.nn
0.10 1.10
1.00
High temperature limit
XH
n.n nnnn.n
0.09999.0
Set at factory
calibration
Sensor initialization
XI
n
0 = flag reset, 1 = flag set
1
Heater temperature
XJ
Laser / LED / Video switching
XL
n
0 = off
1 = on
2 = flashing
3 = switching via external trigger
edge
4 = switching via external trigger
level
0
Sensor model type
XM
X
L = Low Temperature
H = High Temperature
Set at factory
calibration
0 - 20 mA / 4-20 mA analog
output
XO
n
0 = 0 - 20 mA
4 = 4 - 20 mA
4
Firmware revision
XR
e.g. 1.02.11
Set at factory
calibration
Analog firmware revision
XRA
e.g. 1.02.01
Set at factory
calibration
Setpoint / Relay function
XS
n.n nnnn.n
0.0 to 3000°C / 5432°F
Non-zero setpoint value puts unit
in setpoint mode. Setpoint within
unit’s temperature range.
0
Trigger status
XT
n
0 = inactive, 1 = active
0
Trigger control
XTC
n
0 = normal
1 = emissivity/ambient control
0
Identify unit
XU
e.g. E1RL-F2-V-0-0
Set at factory
calibration