43
EN
6. ErrortablesDisplayD1andD0
Category Code Displayedtext Remedy
00 00 Unknown error
Restart the system. If the problem persists,
contact your FLYER specialist retailer.
01
01
02
1D
1E
2C
2D
ECU software
Restart the system. If the problem persists,
contact your FLYER specialist retailer.
02
03
04
1F
20
21
22
23
24
25
26
27
ECUidentication
Verify that the originally supplied
components are connected and restart the
system.
If the problem persists,
contact your FLYER specialist retailer.
03
05
06
07
28
29
2A
2B
17
57
ECU communication error
Check all connections.
Remove and then reinsert the battery. Then
restart the system.
04 09 Remote Initialize Error
Check whether any buttons are stuck.
Restart the system.
05 08 Brake Initialize Error
Check whether the brake lever is stuck or has
dirt on it. Restart the system.
06 0A Frontlight Error
Check the lamp and its cabling. Restart the
system.
07 0B Rearlight Error
Check the rear light/brake light.
Restart the system.
08 0C ECU internal sensor Error
Restart the system. If the problem persists,
contact your FLYER specialist retailer.
09 0D ECUcongurationError
Restart the system. If the problem persists,
contact your FLYER specialist retailer.
0A 0E ECU overtemperature
Your FLYER e-bike is outside the permitted
temperature range.
Let the FLYER cool and restart the system.
0B 0F ECU overcurrent
Restart the system. If the problem persists,
contact your FLYER specialist retailer.
0C 10
average values calculation
error
There is not enough data to calculate
the average values.
0D 11 maintenance request
Take your FLYER e-bike to your FLYER special-
ist retailer as soon as possible for servicing.