EasyManua.ls Logo

FOR-A MFR-6000 - Page 65

FOR-A MFR-6000
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
MFR-8SDOEX
SDI Output Card: 75 ohm, BNC x 8 (16 cards Max.)
Complies with the following standards (75Ω BNC) (Auto reclocking)
- SMPTE424M (3G-SDI)
- SMPTE292M (HD-SDI)
- SMPTE259M (SD-SDI)
- DVB-ASI
Cable Equalization
3G/HD-SDI: 100m (5C-FB cable)
SD-SDI: 200m (5C-2V cable)
MFR-2SDOGB
SDI Output Card
BNC x 2 (12G-SDI or 3G-SDI )
BNC x 6 (3G-SDI)
Complies with the following standards (75Ω BNC)
SMPTE ST 2082-10 (12G-SDI)
SMPTE ST 425-5 (Quad Link 3G-SDI)
I/O delay selection
Delay (H) (0.3H-1H), 1 frame, 1 frame+ Delay (H)
Reference Input
BB: 0.429 Vp-p (NTSC)/0.45 Vp-p (PAL) or Tri-level Sync: 0.6 Vp-p
75Ω BNC x 2, loop-through (Terminate with 75Ω terminator, it
unused.)
Interfaces
MFR-LAN
10/100 BASE-TX, RJ-45 x 2
(For connecting up to 128 RU/GPI units.)
(Second LAN port used in redundant CPU configuration)
PC-LAN
10/100/1000 BASE-T, RJ-45 x 2 (for PC operation)
(Second LAN port used in redundant CPU configuration)
SERIAL
RS-232C/RS-422 (Internal switch), 9-pin D-sub (male) x 1
ALARM
9-pin D-sub 9 (female) x1
(Input: Reset, Output: Power, Fan Alarm)
Temperature
0ºC to 40ºC
Humidity
30% to 85% (no condensation)
Power
100 VAC to 240 VAC ±10%, 50/60Hz IN x 2
Consumption
SDI 144 x 144, Dual CPU/Redundant Power Unit (Maximum
Configuration)
100 V AC to 120 V AC: 1100 VA (1067 W)
220 V AC to 240 V AC: 1078 VA (689 W)
Dimensions
480 (W) x 576 (H) x 400 (D) mm, EIA 13 RU
Weight
73.2 kg (Including all options)
Consumables
Power supply unit: Replace every 5 years
FAN1-3(P-1619): Replace every 4 years.
FAN4-5(P-1620): Replace every 4 years.
FAN6-7(P-1621): Replace every 4 years.

Table of Contents

Related product manuals