No.
Text in display Explanation / Measurement
2 Missing Outlet All functions are disabled if the outlet is missing.
Test the switch.
3 Door open All functions are disabled if the door is open.
If the door is open, empty the dregs drawer.
4 Wrong flash adress A serious error has occurred during the flash process. The flash
address was invalid. It is possible that the CPU is no longer
working and the program must be reloaded with the service tool.
Reprogram the CPU print with the service tool; alternatively,
replace the CPU print.
5 Flash writing error A serious error has occurred during the flash process. It is
possible that the CPU is no longer working and the program must
be reloaded with the service tool. It is also possible that the flah
module in the CPU is faulty.
Reprogram the CPU print with the service tool; if this does not
work, replace the CPU print.
10 Temperature sensor 1 The temperature sensor of the coffee heater is short-circuited
(defective).
11 Temperature sensor 1 The temperature sensor of the coffee heater is interrupted or is
missing.
12 Temp. difference 1 No temperature rise was detected in the coffee boiler over a
heating period of 25 seconds.
13 Overheating 1 The water temperature in the coffee boiler exceeded 120°C.
14 Temperature sensor 2 The temperature sensor for the hot water heater is short-circuited.
(only applicable for EII H)
15 Temperature sensor 2 The temperature sensor of the hot water heater is interrupted or is
missing. (only applicable for EII H)
16 Temp. difference 2 No temperature increase was detected in the hot water boiler over
a heating period of 25 seconds. (only applicable for EIIH)
17 Overheating 2 The water temperature in the hot water boiler exceeded 120°C.
(only applicable for EIIH)
18 Temperature sensor 3 The temperature sensor for Auto-steam is short-circuited
(defective).
19 Temperature sensor 3 The temperature sensor for Auto-steam is interrupted or is
missing.
20 Auto-steam No messurament of temperature diff. (within 15 sec. min. 1°C).
Only used in sw 00.31r04. This fault is off up sw 00.31r05.
21 Auto-steam No messurament of over temperature (120°C).
Only used in sw 00.31r04. This fault is off up sw 00.31r05.
22 Heater timeout 1 The coffee water heater was on for too long.
23 Heater timeout 2 The hot water / steam heater was on for too long.
30 Water supply Coffee boiler / hot water boiler at initialisation of the machine: a
timeout of 300 seconds occurred during filling of the coffee/ hot
water boiler. Check that the water supply is on. If it is, there is
possibly a leak or a pipe is blocked, e.g. due to scale…