Franke Kaffeemaschinen AG
TD-100228 A.doc page 9 / 33
20 Waterfilter
0 [100 lit] [0-100] 0 for OFF
(100 Liter)
Count corresponding to the flow meter for
consumption from the coffee boiler
No count for consumption from the HW/S boiler
21 Milksystem
milk no [milk no] = no milk version
[CF1/2 yes / Sens no] = without milk monitoring
[CF1/2 yes / Sens yes] = with milk monitoring
[CF yes / Sensor yes] = with milk pump and milk monitoring
[CF MUT] = with milk system under tabel
If ‘No’: Following setting 26
22 Milk corr. after
60s [0-120] The milk quantity correction begins after
(Seconds in steps of 1.0s) the programmed time
23 M. correction at
1.0s [0.0-3.0] The milk quantity is increased / corrected by
(Seconds in steps of 0.1s) the programmed time
24 M. correction lim.
1.0s [0.0-10.0] The max. milk quantity correction is limited to
(Seconds in steps of 0.1s) the programmed time
25 M. empty message
3 [0-15] The number of milk/coffee products that can
still be dispensed after the empty message
26 Rinse coffee
10min [0-99] Rinsing after the last dispensed coffee
(Minutes)
27 Rinse milk
3min [0-99] Rinsing after the last dispensed milk
(Minutes)