Franke Kaffeemaschinen AG
TD-100228 A.doc page 14 / 33
8 By-Pass only Top model
0% [0-80] Amount of water in addition to fill volume
(Percent) (breakfast valve Y3)
9 Mill quant. left
2.8s [0.0-15.0] 2.8 seconds for about 8 grams
(Seconds in steps of 0.1s)
Brewing chamber capacity max. 15 grams
10 Mill quant. right
2.8s [0.0-15.0] If both mills are programmed, first the right mill
(Seconds in steps of 0.1s) is addressed by the control system and then
the left mill
(no time reduction!)
11 Control
yes [yes / no] Yes: For monitoring bean quantity level
No: Less than 6 grams of mill quantity
Checking with microswitch brewing unit
12 Preinfusion
0ml [0-99] Water amount of the preinfusion is
(Millilitre) in addition to the fill amount
13 Time preinfusion
0.0s [0.0-25.5] Time after preinfusion
(Seconds in steps of 0.1s) (caution with long waiting time in self-service!)
15 Permanent
no [yes / no] Yes: Output as long as button is pressed
or programmed fill quantity reached
No: Press button once for prog. quantity
Only for milk / froth / water / steam
on normal level