if the fill level in the dipping bowl drops below minimum
-
if the dipping bowl is not used, hence there is no parting agent in the
dipping bowl
NOTE!
If the dipping bowl is used, it should be refilled with parting agent as soon as the
fill level indicator lights up.
NOTE!
The device cleaning function remains available even if the fill level indicator is
illuminated.
(4) Discharge key
for starting the cleaning operation manually, e.g. for adjustment purposes
NOTE!
A cleaning operation can only be triggered manually if the Quick Stop signal is
set and the capacitors are charged
(5) Ready-to-clean indicator
lights up when the device is ready to clean
WARNING!
Risk of serious injury and damage from electric shock.
Once the ready-to-clean indicator (5) lights up, the interconnecting hosepack
must not be disconnected from the base unit.
Before disconnecting the interconnecting hosepack:
Disconnect the base unit power supply
Disconnect the base unit compressed air supply
29