Fronius Robacta TC 1000 - Every 3 Months; Every 6 Months; Every 12 Months; Clean Suction Filter in Parting Agent Container

Fronius Robacta TC 1000
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Every 3 months
NOTE!
Take care never to damage the level sensor when performing maintenance work.
Robacta TC 1000:
1
Drain all the parting agent from the dipping bowl
2
Take the spill tray out of the dipping bowl and dispose of any accumulated
dirt
3
Clean the dipping bowl and spill tray
4
Fill the dipping bowl with new parting agent
Every 6 months
NOTE!
Do not bring the air nozzle too close to electronic parts.
1
Robacta TC 1000 / Robacta TC 1000 ext. Open (base unit and cleaning unit)
and blow clean using dry reduced compressed air
Every 12 months
1
Arrange for a safety inspection to be carried out on the cleaning device by a
Fronius service engineer
Clean suction fil-
ter in parting
agent container
NOTE!
Only use "Robacta Reamer" parting agent supplied by the manufacturer.
The composition of the manufacturer's parting agent is intended specifically for
the Robacta TC. If other manufacturers' products are used, trouble-free opera-
tion cannot be guaranteed.