Screw the base unit and cleaning unit to the un-
derlying surface (foundation) and connect them
to each other
Installation in-
structions
NOTE!
Before installing the base unit and the cleaning unit, ensure that the cleaning
unit interconnecting hosepack is long enough for the intended installation posi-
tions.
Once the devices have been installed, the interconnecting hosepack must lie on
the ground without being under any strain and must not hang in the air.
Screw the base
unit and cleaning
unit P. to the un-
derlying surface
(foundation) and
connect them to
each other
WARNING!
Risk of serious injury and damage from welding residues ejected from the clean-
ing opening on the cleaning unit.
Always position the cleaning unit so any ejected welding residues are caught dir-
ectly in a suitable container at the cleaning station.
WARNING!
Danger from machines toppling over or falling.
This can result in serious personal injury and damage to property.
Different fixings may be required to secure the individual components de-
pending on the type of underlying surface (foundation).
Fixings are therefore not included in the scope of supply of the individual
components. The installer is responsible for selecting the right type of fixing.
1
Position the base unit (1) securely
outside the welding area on a level,
firm and vibration-free surface and
secure using the appropriate fix-
ings
2
Use suitable fixings to bolt the
cleaning unit (2) to the underlying
surface (3)
3
Connect the interconnecting
hosepack (4) to the Cleaning unit
connection socket (page 32) on the
base unit
4
Turn the safety bow on the clean-
ing unit connection socket to pre-
vent the interconnecting hosepack
being unintentionally disconnected
45
EN

Table of Contents