Before commissioning
Operators, main-
tenance person-
nel
WARNING!
Risk of machines starting automatically.
This can result in serious injury and damage to property.
The device must only be operated/serviced by 1 person at a time.
Ensure that there is only 1 person within the working area of the device when
the device is being worked on.
Setup regula-
tions
The cleaning device is tested to IP 21, meaning:
-
protection against penetration by solid foreign bodies with diameters > 12.5
mm (0.49 in.)
-
Protection against vertically falling drops of water
The device must not be set up and operated outdoors. The built-in electrical
parts must be protected from direct wetting.
NOTE!
All components of the cleaning device must be:
Set up at least 1 m (40 in.) away from computers, control lines and the weld-
ing process
Set up with an all-round clearance of at least 0.5 m (19.69 in.) from any sur-
rounding objects, e.g. walls, other devices or objects
Positioned to prevent welding spatter coming into contact with the compon-
ents of the cleaning device
Compressed air
supply specifica-
tions
To ensure that the cleaning device functions correctly, the following compressed
air supply specifications must be met:
-
Establish compressed air supply using a pressure limiter and compressed air
filter
-
Provide compressed air quality conforming to ISO 8573-1:2001, class 7 4 3,
instrument air
-
Solid particle concentration £ 10 mg/m
3
-
Vapour pressure dew point £ + 3 °C
-
Oil concentration £ 1 mg/m
3
Mains connec-
tion
WARNING!
Risk of serious injury and damage due to insufficiently dimensioned electrical
installations.
The mains cable and its fuse must be dimensioned to suit the device being used.
The technical data shown on the rating plate applies.
42