Care, maintenance and disposal
Before each
start-up
1
Check the fill level in the "Robacta Reamer" parting agent nebuliser/parting
agent container and the dipping bowl, top up if necessary
NOTE!
The "Robacta TC Cool / Robacta TC Cool MD" and "Robacta Reamer" parting
agents differ in their composition.
Use the appropriate medium depending on the application concerned.
Daily
NOTE!
Only use solvent-free cleaning products on the devices.
1
Remove any deposits of parting agent or contaminants from the outside of
the base and cleaning units.
Weekly Robacta TC 1000:
1
Empty the spatter tray for welding residues
2
Take the spill tray out of the dipping bowl and dispose of any accumulated
dirt
3
Check the consistency of the "Robacta TC Cool / Robacta TC Cool MD" part-
ing agent. If the "Robacta TC Cool / Robacta TC Cool MD" parting agent is
viscous, add fresh water and stir to mix with the parting agent
4
Check the level sensor in the dipping bowl for dirt and clean if necessary
5
Clean the cleaning opening on the inside
6
Check the "Robacta TC Cool / Robacta TC Cool MD" parting agent container
and the "Robacta Reamer" parting agent container for soiling and clean if ne-
cessary
7
Blow through suction filter in parting agent container 'Robacta Reamer' using
compressed air from the inside outwards through the suction hose (see
Starting up the parting agent nebuliser V on page 54)
8
Check the condition of the brush seal above the cleaning opening. Replace
the brush seal if worn
Robacta TC 1000 ext.:
1
Empty the spatter tray for welding residues on the cleaning unit S.
2
Clean the inside of the cleaning unit cleaning opening
3
Check the parting agent container 'Robacta Reamer' for contaminants and
clean if necessary
4
Blow through suction filter in parting agent container 'Robacta Reamer' using
compressed air from the inside outwards through the suction hose (see
Starting up the parting agent nebuliser V on page 54)
5
Check the condition of the brush seal above the cleaning opening. Replace
the brush seal if worn
79