Starting up the parting agent nebuliser V
Robacta TC
1000: Installing
parting agent
nebuliser V
NOTE!
If the parting agent nebuliser is positioned too high, there is a risk of parting
agent leaking out around the spray holes in the cleaning opening. Position the
parting agent nebuliser below the upper edge of the housing.
NOTE!
Ensure that the length of the parting agent hose between the device and the
parting agent nebuliser does not exceed 1 m (40 in.).
1
Use two screws to secure the part-
ing agent nebuliser (1) to the
cleaning unit installation stand as
shown using the screws supplied
with the parting agent nebuliser
NOTE!
Use the parting agent hoses supplied
with the parting agent nebuliser to
connect the nebuliser to the cleaning
device.
2
Connect the parting agent hose (2)
to the parting agent nebuliser con-
nection on the cleaning device
-
Compressed air supply from
the cleaning device
3
Connect the parting agent hose (3)
to the spray device connection on
the cleaning device
-
Compressed air/parting agent
mixture supply to the cleaning
device
NOTE!
The parting agent spray time must be
set on the robot control.
▶
A spray time of approximately 0.7
seconds is recommended. This
may vary depending on the size of
the gas nozzle.
Cleaning unit S.:
Installing part-
ing agent
nebuliser V
NOTE!
If the parting agent nebuliser is positioned too high, there is a risk of parting
agent leaking out around the spray holes in the cleaning opening. Position the
parting agent nebuliser below the upper edge of the housing.