Fault procedure for Robacta TC 1000 ext.
Fault procedure
WARNING!
Risk of serious injury and material
damage from electric shocks.
The cleaning device has a serious fault
if
▶
the overtemperature (1) and fill
level (2) indicators are flashing at
the same time
▶
the Quick-Stop signal is not active
If this is the case, the interconnecting
hosepack may only be disconnected
from the base unit once the following
safety measures have been met.
Side view of the base unit with open side panel
Safety measures:
1
Ensure that the base unit has been
disconnected from the power sup-
ply
2
Ensure that the cleaning unit has
been disconnected from the com-
pressed air supply
3
Remove the left side panel from
the base unit (as seen from the
front)
4
Ensure that all 6 capacitors (1)
have been fully discharged
5
Refit the side panel
-
The cleaning unit interconnect-
ing hosepack may now be dis-
connected from the cleaning
unit