1
Bolt the parting agent nebuliser (1) to a level, firm and vibration-free surface
close to the cleaning device (2). The installer is responsible for selecting the
installation location and the right fixings
NOTE!
Use the parting agent hoses supplied with the parting agent nebuliser to con-
nect the nebuliser to the cleaning unit.
2
Connect the parting agent hose (3) to the parting agent nebuliser connection
on the cleaning unit
-
Compressed air supply from the cleaning unit
3
Connect the parting agent hose (4) to the spray device connection on the
cleaning unit
-
Compressed air/parting agent mixture supply to the cleaning unit
NOTE!
The parting agent spray time must be set on the robot control.
▶
A spray time of approximately 0.7 seconds is recommended. This may vary
depending on the size of the gas nozzle.
Filling the
"Robacta Ream-
er" parting agent
container with
parting agent
NOTE!
Only use "Robacta Reamer" parting agent supplied by the manufacturer.
The composition of the manufacturer's parting agent is intended specifically for
the Robacta TC. If other manufacturers' products are used, trouble-free opera-
tion cannot be guaranteed.
56