WARNING!
Danger from electrical current.
This can result in serious personal injury and damage to property.
▶
If the interconnecting hosepack needs to be disconnected after the base unit
has been started up, carry out the following steps before disconnecting the
interconnecting hosepack:
▶
Disconnect the base unit power supply
▶
Disconnect the base unit compressed air supply
Bolting the base
unit and cleaning
unit S. to the un-
derlying surface
(foundation) and
connecting them
to each other
WARNING!
Risk of serious injury and damage from welding residues ejected from the clean-
ing opening on the cleaning unit.
Always position the cleaning unit so any ejected welding residues are caught dir-
ectly in a suitable container at the cleaning station.
WARNING!
Danger from machines toppling over or falling.
This can result in serious personal injury and damage to property.
▶
Different fixings may be required to secure the individual components de-
pending on the type of underlying surface (foundation).
▶
Fixings are therefore not included in the scope of supply of the individual
components. The installer is responsible for selecting the right type of fixing.
1
Position the base unit (1) securely
outside the welding area on a level,
firm and vibration-free surface and
secure using the appropriate fix-
ings
2
Position the installation stand (3)
on a level, firm and vibration-free
surface and secure using the ap-
propriate fixings
3
Use suitable fixings to screw the
cleaning unit (2) to the installation
stand (3)
4
Connect the interconnecting
hosepack (4) to the Cleaning unit
connection socket (page 34) on the
base unit
5
Turn the safety bow on the clean-
ing unit connection socket to pre-
vent the interconnecting hosepack
being unintentionally disconnected
46