EasyManua.ls Logo

Fronius Symo Hybrid 3.0-3-S - Status Codes - Class 7 (Control System Issues)

Fronius Symo Hybrid 3.0-3-S
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Code Description Behaviour Remedy
701 -
715
Provides information about
the internal processor status
Warning message on the
display
*)
721
EEPROM has been re-initial-
ised
Warning message on the
display
Acknowledge status code; *)
722 -
730
Provides information about
the internal processor status
Warning message on the
display
*)
746
Error occurred during update
process
Warning message on the
display, update process is
interrupted
Wait for 2 minutes, then start
the update again; *)
751 Time lost
Warning message on the
display
Reset time and date on the
inverter; *)
752
Real Time Clock module
communication error
753
Internal error: Real Time
Clock module is in emer-
gency mode
Time may be inaccurate or
lost (feeding energy into
the grid normal)
Reset time and date on the
inverter
754 -
755
Provides information about
the internal processor status
Warning message on the
display
*)
757 Hardware error in the Real
Time Clock module
Error message on the dis-
play; the inverter is not
feeding any energy into
the grid
*)
758 Internal error: Real Time
Clock module is in emer-
gency mode
Time may be inaccurate or
lost (feeding energy into
the grid normal)
Reset time and date on the
inverter
760 Internal hardware error Error message on the dis-
play
*)
761 -
765
Provides information about
the internal processor status
Warning message on the
display
*)
766
Emergency power limitation
has been activated (max. 750
W)
Error message on the dis-
play
767
Provides information about
the internal processor status
Warning message on the
display
*)
768
Different power limitation in
the hardware modules
772
Data storage unit not avail-
able
773
Software update group 0
(invalid country setup)
775
PMC power stage set not
available
Warning message on the
display
Press “Enter” key to acknow-
ledge error; *)
776 Invalid device type
781 -
794
Provides information about
the internal processor status
Warning message on the
display
*)
*) If the status code is displayed all the time: Notify a Fronius-trained service engineer.
127
EN

Table of Contents