Calculating data volumes
General When using Fronius system monitoring, data is collated that must be transmitted over
the internet.
The data volume must be calculated so that the correct internet connection is selected.
The data volume calculation below provides an overview of the data quantities involved
when using Fronius system monitoring.
Calculating data
volumes
The data volume calculation depends on the number of connected devices in the system
monitoring.
The table below provides an overview of the data volume for various configurations and
time settings (INV = Fronius Symo Hybrid, SM = Smart Meter, BAT = battery module of
the Fronius Solar Battery)
Data volume per day:
Sent Configuration 5 min logging 30 min logging
Hourly
(06:00 - 20:00)
INV 436 kB 305 kB
INV + SM 659 kB 349 kB
INV + SM + 3x BAT 2198 kB 605 kB
INV + SM + 4x BAT 2556 kB 659 kB
INV + SM + 5x BAT 2958 kB 750 kB
INV + SM + 6x BAT 3306 kB 775 kB
INV + SM + 7x BAT 3485 kB 838 kB
INV + SM + 8x BAT 4160 kB 920 kB
Daily INV 30 kB 15 kB
INV + SM 55 kB 20 kB
INV + SM + 3x BAT 228 kB 49 kB
INV + SM + 4x BAT 262 kB 53 kB
INV + SM + 5x BAT 305 kB 63 kB
INV + SM + 6x BAT 344 kB 68 kB
INV + SM + 7x BAT 388 kB 73 kB
INV + SM + 8x BAT 426 kB 83 kB