UNIT Number of connected modules 1 - 16
VER Version XXXX
CON Status of connected modules In the above example, there are 6
connected modules (no. 00 - no.
05).
"Status" display
Display Details Display
M_NO Number of modules displayed 00 - 15
STAT Module status YX (Y: Current status, X: Previous
status)
1X [Pre Charge]: Pre-charging
2X [Initial]: Status at beginning
3X [Normal Chg]: Normal charging
4X [Terminate]: End charging
5X [Normal Dis]: Normal dischar-
ging
6X [Over Volt]: Overvoltage
7X [Over Dis]: Deep discharge
8X
9X [Over Temp C]: Overtemperat-
ure charging
AX [Over Curr C]: Overcurrent char-
ging
BX [Over Temp D]: Overtemperat-
ure discharging
CX [Over Curr D]: Overcurrent dis-
charging
DX [Unbalance]: Cell imbalance
EX [Chg Suspend]: Charging sus-
pended
FX
"Mode, Current, SOC, Voltage" display
Display Details Display
M_NO Number of modules displayed 00 - 15
RSOC Remaining module capacity 0% - 100%
I System module current strength -999.9 A to +999.9 A
V System module voltage 0.0 V to +999.9 V