EasyManua.ls Logo

Fronius Symo Hybrid 3.0-3-S - Data Converter: LED Status Indicators (continued); LED Error Codes and Status Descriptions

Fronius Symo Hybrid 3.0-3-S
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LED 1/2/4/8 (Error
No / Selected ID)
Green General gateway error
State LED Red/
green
General gateway error
State LED Red/
green
Inverter interface state
Power LED Green Inverter supply voltage
"Power" LED(Fronius Solar Battery)
This LED is connected directly to the supply voltage of the 1st serial interface (electrical
isolation is optionally available for this supply).
"1/2/4/8 (Error No / Selected ID)" LED
If these 4 LEDs and the "State" LED all light up steady red at the same time, the error
number is indicated in binary format in accordance with the table in the "Troubleshooting"
section.
"State" LED(Fronius Solar Battery)
Lights up green Status OK
Flashing green Status OK
Flashing green/red Status OK
Lights up red General gateway error (see "Error No." LEDs)
Flashing red Data converter is in configuration/test mode
"State" LED (Fronius hybrid inverter)
Lights up green Initialised and started
Flashing green Initialised
Flashing green/red -
Lights up red General bus error (system error 10)
Flashing red Starts to flash straight after "BusStart" -> Initialisation failed
Starts to flash during actual operation -> Data error
"Power" LED (Fronius hybrid inverter)
This LED is connected directly to the supply voltage of the interface.