bAt | oFF
Welding is not possible.
The battery of the OPT Easy Documentation is empty
To reset the service code, press the arrow key - the display shows no |
dAt;
Contact service (to change the battery);
After changing the battery, set the date and time in the 2nd level of
the service menu;
see page 89
Cause:
Remedy:
Err | doc
Welding is not possible.
Error writing data;
Internal documentation error;
Communication error;
Switch the power source off and back on
Cause:
Remedy:
Err | USb
Welding is not possible.
Invalid file system on USB flash drive;
General USB error
Unplug USB flash drive
Cause:
Remedy:
USB | full
Welding is not possible.
The plugged in USB flash drive is full
Unplug USB flash drive, plug in new USB flash drive
Cause:
Remedy:
116