Chapter 7
Power Control Setup
Perform power control settings as required.
Power control settings must be performed if the Auto Power function (AC automatic linkage mode) is ena-
bled, the Power Resume function (automatic power recovery mode) is enabled, the power synchronized unit
is connected, or the Wake On LAN function is used.
For details on the settings, refer to "Configuration Guide (Web GUI)".
7.1 Setup of the Auto Power Function and/or the Power Resume
Function
To automatically turn on the ETERNUS AF when AC power is supplied or when power is restored after a power
failure, use ETERNUS Web GUI to enable the Auto Power function and/or the Power Resume function.
Auto Power function (AC automatic linkage mode)
When the Auto Power function is enabled, the
ETERNUS AF is automatically turned on when AC power is
supplied.
The Auto Power function is disabled for the factory default setting.
Power Resume function (automatic power recovery mode)
When the Power Resume function is enabled, the ETERNUS AF is automatically turned on when the power
supply is restored after a power failure.
The Power Resume function is disabled for the factory default setting.
Table 7.1 shows how the ETERNUS AF operates when the Auto Power function and the Power Resume func-
tion are enabled or disabled.
Table 7.1 ETERNUS AF Operation according to the Settings of the Auto Power Function and the Power Resume
Function
Settings for the power control functions How the ETERNUS AF operates
Auto Power function is disabled
Power Resume function is disabled
The ETERNUS AF is not automatically turned on even when AC power is
supplied or when power is restored after a power failure.
Auto Power function is enabled
Power Resume function is disabled
The ETERNUS AF is automatically turned on when AC power is supplied.
The ETERNUS AF
is not turned on even when power is restored after a pow-
er failure.
Auto Power function is disabled
Power Resume function is enabled
The ETERNUS AF is not turned on automatically even when AC power is
supplied.
The ETERNUS AF
is automatically turned on when power is restored after a
power failure.
Auto Power function is enabled
Power Resume function is enabled
The ETERNUS AF is automatically turned on when AC power is supplied and
when power is restored after a power failure.
105
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays
Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0