8.2 Server Connection Setup
Set up the server as required to connect to the ETERNUS AF.
The IP address to connect to the iSCSI network must be set on the server before the
ETERNUS AF is connected.
After the server connection setup is completed, confirm that the volumes in the ETERNUS AF can be recog-
nized by the server.
Figure 8.1 Connection Configuration with Servers
iSCSI multipath
connection
Server (host) ETERNUS AF
LAN card#0
A
LAN card#1
B
CA#0 Port#0
C
CM#0
CA#0 Port#0
D
CM#1
8.2.1 iSCSI Initiator Parameter Settings (Connection Information Settings)
Use the iSCSI Software Initiator to set the iSCSI initiator parameters.
After performing the settings, check the connection to the
ETERNUS AF.
Turn on the ETERNUS AF while its iSCSI port is connected to the LAN port for iSCSI connection on the server
with the host interface cable. After confirming that the ETERNUS AF is in READY status, turn on the server.
1 On the [iSCSI Initiator Properties] screen, click the [Discovery] tab.
Chapter 8 SAN Connection Settings
8.2 Server Connection Setup
119
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays
Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0