Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
776
• Automatic Log Transmission
• Proxy Server
• Port No.
• Connection Type
• User Name
Description Select whether to enable or disable the automatic log transmission.
When "Automatic Log Transmission" is enabled and notification of Error Severity Level or
Warning Level occurs, a log is collected and sent to the AIS Connect server in
approximately five minutes. The maximum size of a log is 1.44MB. Note that I/O Module
logs are not included.
If a send log request is already performed once log collection is complete, send log
requests are not performed. If a communication error occurs and a connection to the AIS
Connect server cannot be established, logs cannot be sent. A log that fails to be sent is
not resent.
Input condition/
Display contents
• Enable
• Disable
Description Input the IPv4 address or the FQDN of the proxy server.
Make sure to input "Proxy Server" and "Port No." together.
If a proxy server is not used, this item does not need to be set.
Input condition/
Display contents
• For IPv4 address
xxx.xxx.xxx.xxx
xxx: 1 - 255 for the top field (decimal)
xxx: 0 - 255 for other fields (decimal)
• For FQDN
Up to 63 alphanumeric characters and symbols ("." (dot), ":" (colon), "-" (hyphen),
and "_ " (underscore) can be used)
Description Input the port number of the proxy server.
Make sure to input "Proxy Server" and "Port No." together.
If a proxy server is not used, this item does not need to be set.
Input condition/
Display contents
0 - 65535
Description Select the communication method for the proxy server.
Input condition/
Display contents
• HTTP
Basic/NTLM HTTP authentication
• SOCKS
SOCKSv5 authentication
Description Specify the user name for the proxy server authentication.
If a proxy server is not used, this item does not need to be set.
Input condition/
Display contents
Up to 32 alphanumeric characters and symbols