Chapter 4 Troubleshooting
4.6 Tape Library Error Codes
FUJITSU Storage ETERNUS LT40 S2/LT60 S2 LTO Library Installing, Starting Up and Maintaining
Copyright 2018 FUJITSU LIMITED P3AM-5392-07ENZ0
83
C7 Cannot Upgrade from USB Retry of Firmware upgrade, if not successful
contact technical support
D0 ROM error.
ROM checksum incorrect
Retry of Firmware upgrade, if not successful
contact technical support
D1 RAM error.
Power on Self Test (POST) has failed,
Retry operation; after several occurrences contact
technical support
D2 NVRAM error.
R/W operation to NVRAM has failed
Retry operation; after several occurrences contact
technical support
D3 CTC Error.
Timer unit has failed during POST.
Retry operation; after several occurrences contact
technical support
D4 UART Error.
Frame overrun or Parity Error on serial Interface.
Retry operation; after several occurrences contact
technical support
D5 Display Error Communication to display failed Retry operation; after several occurrences contact
technical support
D6 Memory Error, Stack and heap overflow. Retry operation; after several occurrences contact
technical support
D7 Fatal system error Retry operation; after several occurrences contact
technical support
D8 Data base error Retry operation; after several occurrences contact
technical support
DA In Library Verify Test the barcode reader has read
different barcode data for the same cartridge
label
Check barcode label on scratch cartridge and run
Library Verify Test again. If the error recurs,
contact technical support
DB Warning event! t. b. d.
DC
I
2
C Bus Failure
Retry operation; after several occurrences contact
technical support
DD Warning event! t. b. d.
DE Warning event! t. b. d.
DF Warning event! t. b. d.
E0 Incompatible magazine detected Check type of lowest left magazine
F0 Drive Overtemperature Condition
The subcode indicates which drive is affected
Example:
Subcode 01: drive #1
Check ambient temperature conditions and check
all fans, after several occurrences contact
technical support
F1 Drive Communication Error,
Library controller has lost communication to drive
The subcode indicates which drive is affected
Example:
Subcode 01: drive #1
Retry operation; if not successful contact technical
support
F2 Drive Sled not present
The subcode indicates which drive sled is affected
Example:
Subcode 01: drive sled #1
Retry operation; if not successful contact technical
support
F3 Drive Hardware Error
The subcode indicates which drive is affected
Example:
Subcode 01: drive #1
Cycle Power, after several occurrences contact
technical support
Error Code Description User Action