Note
-
In
a
building
block
configuration
with
direct
connections
between
chassis,
BB#00
is
the
chassis
of
the
master
XSCF.
In
a
building
block
configuration
with
connections
through
crossbar
boxes,
BB#80
is
the
chassis
of
the
master
XSCF.
If
the
MASTER
LED
of
BB#00
or
BB#80
does
not
go
on,
the
master
chassis
may
have
been
switched.
Check
the
MASTER
LED
of
the
XSCF
of
BB#01
or
BB#81.
If
it
has
been
switched,
connect
the
system
management
terminal
to
the
chassis
whose
MASTER
LED
is
on.
b.
When
using
an
expansion
rack,
open
the
rear
door
of
the
rack
and
push
in
all
the
CB
switches
on
the
PDU.
When
pushed
in,
a
CB
switch
is
turned
on.
When
pulled
up,
the
switch
is
turned
off.
A
in
Figure
3-3
indicates
the
locations
of
the
CB
switches
for
single-phase
power
feed.
B
in
the
figure
indicates
the
locations
of
the
CB
switches
for
three-phase
power
feed.
A
PDU
has
12
CB
switches,
so
there
are
24
switches
per
rack.
4.
Check
the
XSCF
unit
LEDs.
a.
The
CHECK
LED
of
the
XSCF
unit
goes
on
for
an
instant
immediately
after
the
input
power
is
turned
on.
b.
The
READY
LED
of
the
XSCF
unit
flashes
during
XSCF
initialization
and
stays
on
after
the
initialization
completes.
c.
For
a
building
block
configuration,
the
MASTER
LED
of
only
the
XSCF
unit
of
the
master
XSCF
goes
on.
Figure
6-4
  
Rear
of
the
SPARC
M10-1
Chapter
6
 
Performing
an
Initial
System
Diagnosis 181

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals