Table
1-5
  
Workflow
for
connections
through
crossbar
boxes
(continued)
Step
(work
time
(*1)) Work
description Referenc e
Initial
diagnosis
(approx.
117
minutes/approx.
151
minutes)
12 Connect
the
system
management
terminal
to
the
chassis.
"6.1
Connecting
the
System
Management
Terminal
to
the
Chassis"
Required
13 Confirm
that
the
chassis
identification
IDs
(BB-IDs)
are
set.
"6.2.1
Checking
the
BB-ID
settings
(for
the
SPARC
M10-4S)"
Required
14 Turn
on
the
input
power. "6.2.2
Turning
on
the
input
power
and
starting
the
XSCF"
Required
15 Log
in
to
the
SPARC
M10-4S,
and
check
the
firmware
version
number,
altitude
setting,
and
time
setting.
"6.3
Logging
In
to
the
XSCF"
"6.4
Checking
the
XCP
Version"
"6.5
Checking
the
Altitude
Setting"
"6.6
Checking
the
Time
Setting"
Required
16 Perform
an
initial
diagnosis
test
on
the
physical
system
board
(PSB).
"6.7
Performing
a
Diagnosis
Test" Required
17 Check
the
status
of
mounted
components.
"6.8
Checking
the
Component
Status"
Required
Initial
system
settings
(approx.
130
minutes/approx.
200
minutes)
18 Set
the
password
policy. "7.1
Setting
the
Password
Policy" Required
19 Set
a
user
account
and
password. "7.2
Setting
a
User
Account
and
Password"
Required
20 Configure
the
telnet
or
SSH
service. "7.3
Configuring
the
Telnet/SSH
Service"
Required
21 Configure
the
HTTPS
service. "7.4
Configuring
the
HTTPS
Service"
Required
22 Configure
the
XSCF
network. "7.5
Configuring
the
XSCF
Network"
Required
23 When
duplicating
memory,
configure
memory
mirroring.
"7.6
Configuring
Memory
Mirroring"
Optional
24 Create
the
PPAR
configuration
information
(PCL).
"7.7
Creating
a
Physical
Partition
Configuration
List
(PCL)"
Required
25 Assign
the
system
board
(PSB)
to
the
physical
partition.
"7.8
Assigning
a
System
Board
(PSB)
to
a
Physical
Partition
(PPAR)"
Required
26 Set
a
CPU
operational
mode
for
the
physical
partition.
"7.9
Setting
a
CPU
Operational
Mode
for
the
Physical
Partition"
Optional
27 Clear
the
difference
between
the
system
time
and
physical
partition
(PPAR)
time.
"7.10
Synchronizing
the
Physical
Partition
(PPAR)
Time
and
XSCF
Time"
Required
28 Add
a
CPU
Activation
key
to
the
system.
"7.11
Registering
a
CPU
Activation
Key"
Required
(*6)
29 Assign
CPU
resources
to
the
physical
partition.
"7.12
Assigning
CPU
Core
Resources"
Required
Chapter
1
 
Understanding
the
Installation
Flow 11

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals