XSCF>

diagxbu

-y

-b

01

-p

00
XBU

diagnosis

is

about

to

start,

Continue?[y|n]

:y

Power

on

sequence

started.

[7200sec]


0.....

30.....

60..end

XBU

diagnosis

started.

[7200sec]


0.....

30.....

60.....

90.....120.....150.....180.....210.....240...../

270.....300.....330.....360.....390.....420.....450.....480.....510.....\

540.....570.....600.....630.....660.....690.....720.....750.....780.....\

810.....840.....870.....900.....930...end

completed.

Power

off

sequence

started.

[1200sec]


0.....

30.....

60.....

90.....120.....150.....180.end

completed.
XSCF>

showlogs

error
XSCF>

showpcl

-p

0
PPAR-ID

LSB

PSB

Status
00

Running

00

00-0
c.
Execute
the
showlogs
error
command,
and
confirm
that
no
error
is
displayed.
If
an
error
is
displayed,
see
"A.2.2
Checking
the
contents
of
logs."
d.
Execute
the
showhardconf
command
to
check
the
configuration,
status,
and
quantities.
For
details,
see
"6.8
Checking
the
Component
Status."
5.
The
installation
expands
the
1BB
configuration
to
a
multiple-BB
configuration.
So,
configure
the
XSCF
network.
For
details,
see
"7.5.2
Setting
an
Ethernet
(XSCF-LAN)
IP
address"
and
"7.5.3
Setting
a
takeover
IP
address."
After
configuration,
execute
the
applynetwork
command
to
apply
the
settings,
and
confirm
that
they
were
reflected.
Then,
execute
the
rebootxscf
command
to
complete
settings,
and
go
to
the
next
step.
For
details
on
the
procedure,
see
"7.5.6
Applying
network
settings."
6.
To
configure
memory
mirroring
for
the
insta lled
SPARC
M10-4S,
set
memory
mirror
mode.
For
details,
see
"7.6
Configuring
Memory
Mirroring."
If
you
do
not
use
memory
mirror
mode,
this
step
is
not
necessary.
7.
Register
the
system
board
of
the
installed
SPARC
M10-4S
in
the
physical
partition
conf iguration
list.
a.
Execute
the
showpcl
command
to
check
the
physical
partition
configuration
list.
b.
Execute
the
setpcl
command
to
register
a
system
board
in
the
physical
partition
configuration
list.
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
ï½¥
July
2015246

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals