1. INITIAL SETTINGS AND ADJUSTMENTS
1-8
1.2.4 [Route Transfer] window
1. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.
2. Click [Route Transfer] on the menu bar.
3. To transfer data to a specified network, select [Connected] from the [Connection]
pull-down list.
4. Click [Save] on the info bar. Several confirmation messages appear. Click [OK] to
reboot the system. To discard all changes, click [Discard Changes].
1.2.5 [Application] window (setting is not required)
Do not change the setting on the [Application] window of the [Basic Setting] menu.
Confirm that [Primary] is set to [ECDIS], if the setting is not [ECDIS], change it to [EC-
DIS].
Menu item Description
[Connection] Select [Connected] to transfer the data.
[Transmission Rate] Set the transmission rate.
[Network] Select the destination network for route data.
[Destination] Set the IP address and port of the destination.
[Initial Value of Sequence
No.]
Set the initial value for the binary transmission
sequence number (IEC61162-450 compliant) to
be used when transferring route data to another
system.